Installation
Site Requirements
Space
Counter able to support 180 lbs (PAF Accessory Included).
Minimum clearance of 6” between the machine side and the wall or another appliances
Counter area able to accommodate machine’s footprint with six inches of clearance in the rear
for air ow and air lter cleaning.
Dispenser performs better if not placed near any heating appliance that exhausts heat on and
around dispenser.
Ultra-1 approx. dimensions (H 32 x W 8 x D 24.5)
Ultra-2 approx. dimensions (H 32 x W 16 x D 24.5)
Plumbing (PAF Only)
A shut-off valve should be installed in the line before the machine.
Cold water with an operating pressure between 20 and 90 psi (138 and 690kpa) from a 1/2 inch
or larger supply line with a shut off valve.
A strainer assembly should be installed in line prior to the exible water line.
Plumbing (LAF with Water to Product Ratio Brix Pump with Shut Off)
Cold water with an operating pressure between 20 and 90 psi (138 and 690kpa) from a ½ inch or
larger supply line with a shut off valve.
Water pressure regulator required and set to 50 psi (345kpa) or SHURo water pressure
reducing valve.
Double check valve with vent required after pressure regulator.
3 - Way Sanitizing Valve required within 6 inches of the brix pump
Use 3/8 inch I.D. FDA approved exible beverage tubing and stainless steel ttings with Oetiker
clamps.
Water Treatment
Cold water hook-up only.
Adequate space for water lter and maintenance.
Water lter or water cartridge purged before machine installation.
Installation date recorded on water lter decal.
Electrical
120VAC
Dedicated 15AMP Circuit with proper breaker and receptacle
Receptacle within 5 feet of machine
Mating connector must be NEMA 5-15R
Location of the Serial Number
The machine’s serial number is located on the data plate, which is located on
the right side panel. The serial number half tag can be found on the inside of the
machine on the main machine frame.