11
Note the voltage and current type as specied on the type
label.
→ Check that seal is tted correctly.
→ Connect and tighten the cable plug (tightening torque: max. 1 Nm).
The cable plug can be turned by 4 x 90°.
Control of pulse version
Correct polarity is essential to ensure that the device func-
tions: Note identication on the upper side of the coil.
Pulse duration at least 50 ms.
Terminal 1
Terminal 2
Protective conductor connection
Fig. 4: Pulse version
Polarity Specications Terminal connections
- Switch ON +
Valve (P seat)
will be opened
(+) on terminal 2,
(–) on terminal 1
+ Switch OFF -
Valve (P seat)
will be closed
(+) on terminal 1,
(–) on terminal 2
Tab. 2: Control of pulse version
Use only cable plug without electrical wiring for pulse
versions.
6.3 Rotation of coil
WARNING!
Risk of electric shock.
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock.
▶ Check protective conductor contact after installing the coil.
Overheating, risk of re.
Connection of the coil without pre-assembled valve will result in
overheating and destroy the coil.
▶ Connect the coil with assembled tting only.
english