33
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
12.3.Technicalparameters
Table 6
Pell 25 Pell 40 Pell 70 Pell 90 Pell 150
Nominal heat output kW 25 40 70 90 150
Min./Max. heat output kW 5÷25 10÷40 15÷70 30÷90 50÷150
Average
power
consumption
Firing-Up mode
Operate mode
Self-cleaning mode
W
W
W
~
400
~
60÷70
~
1300
~
400
~
60÷70
~
1300
~
400
~
70÷110
~
1300
~
400
~
70÷110
~
1300
~
400
~
70÷110
~
1300
Electric power supply V/Hz
~
230/50
~
230/50
~
230/50
~
230/50
~
230/ 50
Overall
dimensions
Height H
Width L / Depth D
mm
mm
575
615/245
575
700/300
575
750/350
575
750/350
650
750/350
Minimal recommended
size of boi ler combustion
chamber
Height
Width
Depth
mm
mm
mm
250
250
390
350
450
550
350
450
600
500
500
450
500
500
800
Required chimney draught Pa 25 27 30 32 40
Boiler mounting kit
P P P P P
Heat-output adjustment
P P P P P
Combustion Efficiency
Emitted heat
%
%
96
92
96
92
96
92
96
92
96
92
Weight of burner kg 17 13 26 28 32
Burner body
Length
Width
Height
A, mm
B, mm
C, mm
390
245
360
390
245
360
390
245
360
390
245
360
390
330
410
Combustion
chamber housing
Diameter
Length
D, mm
E, mm
140
220
170
300
170
340
170
340
210
340
Feeder chute
Diameter
Length
G,mm
I,mm
60
250
60
250
60
250
60
250
60
250
Automatic cleaning system P
P P P P P
Built-in CPU control unit U
P P P P P
Burner flame, length* F, mm 750 1000 1500 1600 2000
Pellet auger
Diameter
Length
M, mm
75
1500
75
1500
75
1500
75
1500
75
1500
Flexible connection
Diameter
Length
N, mm
60
700
60
700
60
700
60
700
60
700
Weight of auger kg 6 6 6 6 6