12 | Decommissioning and disposal
/ 44
0870S03226_VRD 2072-3108_-
0000_IM_en
12 Decommissioning and disposal
12.1 Stop operating vacuum system
Disconnect the vacuum system from the power supply.
Vent all connected pipes to atmospheric pressure.
Disconnect all connections.
If the vacuum system has to be stocked, observe following:
For more information, see storage (chap. 5).
Version with oil/water heat exchanger:
Interrupt the water supply (only version with oil/water heat exchanger).
Disconnect the water supply (only version with oil/water heat exchanger).
Blow the cooling water supply free with compressed air.
12.2 Disassembly and disposal
Drain the oil.
Remove the exhaust filters.
Remove the oil filter.
Remove all electrical components.
Separate the hazardous waste from the vacuum pump.
Dispose of hazardous waste according to the applicable legal provisions.
Dispose of the vacuum system as waste metal and electronic scrap.