5 | Storage
0870S03226_VRD 2072-3108_-0000_IM_en
13 /
44
5 Storage
ATTENTION!
Danger of damage to the vacuum pump drive!
Long storage periods may cause capacitors in the drive to be weakened by electro-
chemical condensation. In the most detrimental case, this may cause short-circuit and
thereby destruction of the drive.
The vacuum pump should therefore be connected to the power supply for 30 minutes
every 18 months.
Proceed as follows for storage:
Close all openings with the protective caps included in the scope of delivery (penetra-
tion of dirt and water is prevented)
If storage for more than 3 months is intended:
Secure loose cables
Drain all process and operating media
Clean and dry the vacuum system (Prior to storing make absolutely sure that all parts
are clean, drained and dry)
Where necessary use oil for conservation
Wrap the vacuum system in corrosion-inhibiting film.
Store the vacuum system in a protected, dry and dust-free room at a temperature be-
tween 0 and 40 °C.