44
EN
Adjusting the soft water supply
Display shows SEt
Display flashes
Adjusting the soft water supply
(only valid for 4° blended water hardness)
Find the litre values from the table, in accordance
with their inlet water hardness and adjusted working
range:
Supply wa- Operating range
ter hardness tP1 tP2 tP3
°d litre litre litre
10 1500 2166 3000
11 1286 1857 2571
12 1125 1625 2250
13 1000 1444 2000
14 900 1300 1800
15 818 1182 1636
16 750 1083 1500
17 692 1000 1385
18 643 928 1286
19 600 866 1200
20 563 812 1125
21 529 765 1059
22 500 722 1000
23 474 682 947
24 450 650 900
25 429 619 857
26 409 591 818
27 391 565 783
28 375 541 750
29 360 520 720
30 346 500 692
31 333 481 666
32 321 464 643
33 310 448 621
34 300 433 600
35 290 419 581
Finish programming
The new soft water supply is only displayed after
the next regeneration cycle.
e.g.
0563 L
563 L
Example:
Inlet water
hardness 20 ° d
Operating range tP1
SEt
Uhrzeit
448L
0448 L