C-COM Satellite Systems Inc.
Step 4: Testing the 7000 Controller.
a. Disconnect the sensor cable from the 7000 Controller and place the paper clip on the
connector shorting out pins corresponding to the Switch you wish to test.
5&9 and 5&18 for Elevation ST
b. From the iNetVu Mobile 7000 Controls screen does the Elevation ST come ON?
If YES, this concludes the Sensor Cable has failed
If NO, this concludes the 7000 Controller has failed
Please contact C-COM Technical Support for further assistance at