EasyManuals Logo

Cadex C7400ER User Manual

Default Icon
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #153 background imageLoading...
Page #153 background image
Detailed
Message
Code Reasons Solutions
DISCHARGING 7
Battery is being discharged
normally.
Program will continue when
cycle has completed.
HIGH CELL
RESISTANCE
135
Battery resistance has
exceeded the OhmTest
setpoint threshold
Program is complete (see To
edit the OhmTest Setpoint,
page 36).
HIGH CELL
RESISTANCE
136
The battery resistance has
exceeded the OhmTest
setpoint threshold – this
message is for BatteryShop
Program is complete (see To
edit the OhmTest Setpoint,
page 36).
HOT BATTERY
ON TRICKLE
CHARGE
159
Battery temperature has
exceeded its maximum
setting after service has
ended and battery was on
trickle charge. The trickle
charge stops.
Verify that the mAh rating of
the battery matches the C-
code mAh setting.
Reduce the Charge rate in the
C-code. Reduce the trickle-
charge rate or the maximum
standby voltage in the
extended C-code.
Lower the room temperature.
HOT BATTERY,
LOW VOLTAGE
156
Battery temperature went to
its maximum setting in the
initial charge cycle. Service
terminates.
Reduce the Charge rate in the
C-code. Allow battery to cool
before servicing the battery
again.
The internal cells may have
shorted or the battery is old.
Either monitor battery use or
discard.
137