49
OPERATING INSTRUCTIONS
LOCK FEATURES
The locking features, TEMPERATURE LOCK and SPA LOCK, are enabled from the control panel by a specific combination of buttons. Once enabled, a lock will remain
active until the specific button combination is applied to disable the lock. Even if power is disconnected from the spa and soon thereafter reapplied (such as a power
outage), the lock will remain in place.
SPA LOCK
To activate the Spa Lock feature, press “SET” button. When the “SET” icon flashes push “TEMP ▼” button. Do not press any other buttons on the control panel
until the “SET” icon stops flashing. The SLOC symbol is displayed and the “SET” icon will stop flashing. To deactivate the Spa Lock, press “SET” button. When
the “SET” icon flashes press the “TEMP ▼” button. Do not press any other buttons on the control panel until the “SET” icon stops flashing. The SLOC symbol
is no longer illuminated and the “SET” icon will stop flashing .
TEMPERATURE LOCK
To activate the Temperature Lock feature, press “SET” button. When the “SET” icon flashes push “TEMP ▲”button. Do not press any other buttons on the
control panel until the “SET” icon stops flashing. The TLOC symbol is displayed and the “SET” icon will stop flashing. To deactivate the Temperature Lock, press
“SET” button. When the “SET” icon flashes press the “TEMP ▲”button. Do not press any other buttons on the control panel until the “SET” icon stops flashing.
The TLOC symbol is no longer illuminated and the “SET” icon will stop flashing .
FILTER CYCLES
When the spa is first powered up, the automatic filter cycle will wait 10 minutes before starting. Your spa will automatically turn the first filter cycle on
for 60 minutes on low speed. The second filter cycle will activate for 30 minutes, 12 hours later. The filter cycle icon, F1 or F2, will be displayed in the
control panel.
NOTE: The optional Monarch
®
or PureWater
TM
ozone systems only work during the filter cycles.
To modify the length of either filter cycle:
A. Press and hold the
“SET”
button for approximately three seconds (The filtration ion will flash during programming).
B. Press the “LIGHT” button to select the Filter Cycle 1 or 2 (a F1 or F2 will flash in the display). NOTE: Each filter cycle can be set independently.
C. Using the TEMP ▲ or the TEMP ▼ button, adjust the length of filtering time desired (0 to 6 hours).
D. Programing will then be saved 10 seconds after the last button is pushed.
The filter cycle will activate the low speed of the jet pump for the entire cycle. When activated, the filter cycle icon on the display is turned on. If the temperature
exceeds the set point by one degrees C for more than three hours, the system will suspend the FILTER cycle and the filter cycle icon will blink for the remaining filter
cycle time. Should the temperature cool down to 0.5 degree C (1.5 degree F) within the set point before the end of the cycle, the cycle will resume for the rest of the
time. Should you use the spa during the filter cycle by placing the jet pump on high speed, the filter cycle icon will blink. Once the jet pump has been shut off, a ten
minute tranquil mode begins (filter cycle icon will be blinking during tranquil mode) before the filter cycle will resume. The blinking filter cycle icon indicates that the filter
cycle timer is still counting, but the cycle has been temporarily interrupted.
NOTE: The interrupted time of a filter cycle is not extended after the filter cycle resumes. Power interruptions of the spa will reset the filter cycle to the default last set
cycle time and begin 5 minutes after spa regains power.
OPERATION NOTE: For proper water-circulation during filtration cycles, rotate the air control valves counterclockwise to the off position.
MANUAL CLEAN CYCLE
The clean-up cycle operates in the following manner: Jet pump 1 runs for ten minutes on high speed.
This system is initiated by pressing the “SET” button, then “JETS” button. The Filter and Jets icon will flash.
SLEEP MODE
The Sleep Mode operation is a feature that minimizes pump operation during evening hours. For example, if Filter Cycle 1(F1) is set to activate at
8:00am, by default, Filter Cycle 2 (F2) will be set to activate at 8:00pm (12 hrs. later). During 8:00pm to 8:00am, if the spa should call for heat, the
pump and heater will activate to heat the spa. However, when in Sleep Mode, should the spa call for heat, the pump and heater will be
suspended until the activation of Filter Cycle 1 at 8:00am, to minimize pump activation during evening hours. NOTE: If water temperature drops below 80 degrees,
pump and heater will automatically activate to prevent temperature from dripping further.
To activate the Sleep Mode feature, press and hold
“TEMP ▲ “ and
“TEMP ▼“ buttons together for 3 seconds. This will activate the feature and override the normal
filter cycle operation. When these buttons have been engaged, the Sleep Mode icon will illuminate on the control panel display, indicating the feature is active. To
deactivate this feature, simply press and hold the specific buttons in the same manner once again.