META_S_Rev6-s11 3 / 80
QUICK START
ENGLISH
Before starting the system, read the mèta instruction manual
for installation
(chap.6), startup and operation (chap.8) .
1. Set parameter AP01 as dened in
paragraph 8.3.
After starting, with the pump fully primed and running
(see paragraph 8.4), carry out the
following check.
2 Check that the following conditions are met:
2.1. Open a tap to get half of the ow rate (≃ 4-5 litres per minute); in these conditions, the
pump must work continuously.
½ opened tap
(≃ 4-5 l/min)
Continuous
operation
If the pump has an intermittent operation (discontinuous ow) decrease the parameter AP06
by 0,1bar steps as long as the operation is continuous.
2.2. Close the tap at ¼ of the ow rate (≃ 2 litres per minute); in these conditions, the pump
must work intermittently.
¼ opened tap
(≃ 2 l/min)
Intermittent
operation
If the pump has a continuous operation (continuous ow) increase the parameter AP06 by
0,1bar steps as long as the operation is intermittent.
3. Once step 2.2 has been veried, check step 2.1 again to ensure that both steps are satised
with the same value of parameter AP01.
If errors appear during the procedure, see chap. 12, 13 and 14 of the instruction manual.