QUICK START
ENGLISH
Before starting the system, read the mèta instruction manual
for installation
(chap.6), startup and operation (chap.8) .
1. Set parameter AP01 as dened in
paragraph 8.3.
After starting, with the pump fully primed and running
(see paragraph 8.4), carry out the
following check.
2 Check that the following conditions are met:
2.1. Open a tap to get half of the ow rate ( 4-5 litres per minute); in these conditions, the
pump must work continuously.
½ opened tap
( 4-5 l/min)
Continuous
operation
If the pump has an intermittent operation (discontinuous ow) decrease the parameter AP06
by 0,1bar steps as long as the operation is continuous.
2.2. Close the tap at ¼ of the ow rate ( 2 litres per minute); in these conditions, the pump
must work intermittently.
¼ opened tap
( 2 l/min)
Intermittent
operation
If the pump has a continuous operation (continuous ow) increase the parameter AP06 by
0,1bar steps as long as the operation is intermittent.
3. Once step 2.2 has been veried, check step 2.1 again to ensure that both steps are satised
with the same value of parameter AP01.
If errors appear during the procedure, see chap. 12, 13 and 14 of the instruction manual.