Chapter 3: System planning Site planning
Page
3-16
• If the tower is greater than 61 m (200 ft) in height, the drop cable shield must be grounded at the
tower midpoint, and at additional points as necessary to reduce the distance between ground
cables to 61 m (200 ft) or less.
• In high lightning-prone geographical areas, the drop cable shield must be grounded at spacing
between 15 to 22 m (50 to 75 ft). This is especially important on towers taller than 45 m (150 ft).
For roof installations (Figure 48), use the following additional criteria:
• The drop cable shield must be bonded to the building grounding system at its top entry point
(usually on the roof).
• The drop cable shield must be bonded to the building grounding system at the entry point to the
equipment room.
Lightning Protection Unit (LPU) location
Find a location for the bottom LPU that meets the following requirements:
• The bottom LPU can be connected to the drop cable from the ODU.
• The bottom LPU is within 600 mm (24 in) of the point at which the drop cable enters the building,
enclosure or equipment room within a larger building.
• The bottom LPU can be bonded to the grounding system.

Table of Contents

Other manuals for Cambium Networks PMP 450 AP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cambium Networks PMP 450 AP and is the answer not in the manual?

Cambium Networks PMP 450 AP Specifications

General IconGeneral
BrandCambium Networks
ModelPMP 450 AP
CategoryWireless Access Point
LanguageEnglish

Related product manuals