23 - Manual FA01310-EN - 02/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Sensor type
Set the type of control device.
F14 Sensor type 0 = Transponder selector switch
1 = Keypad selector (default)
Additional light
Choose the operating mode of the lighting device connected to the output.
F18 Additional light 0 =Flashing beacon (Default)
1 = Cycle light.
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
F19 Automatic close OFF (Default)
From 1 to 180 seconds
Automatic closing after partial opening
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Do not deactivate the function [Automatic close].
F20 Automatic partial close OFF
From 1 to 180 seconds (default: 10 seconds)
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21 Pre-flashing time OFF (Default)
From 1 to 10 seconds
Opening slowdown speed
Set the slowdown speed during opening (as a percentage of the maximum speed).
This function appears only if the [Encoder] function is active.
F30 Opening slowdown speed OFF (Default)
1 = High
2 = Medium
3 = Low
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
This function appears only if the [Encoder] function is active.
F34 Travel sensitivity 10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity