24 - Manual FA01310-EN - 02/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Slowdown sensitivity
Adjust the obstacle-detection sensitivity level during slowdown.
This function appears only if the [Encoder] function is active.
F35 Slowdown sensitivity 10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity
Partial opening point
Determine the gate partial opening point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F36 Part. open point 10% to 80% (Default 80%)
Opening slowdown point
Set the opening slowdown start point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F37 Opening slowdown point 5% to 30% (Default 15%)
Closing slowdown point
Set the closing slowdown start point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F38 Closing slowdown point 5% to 30% (Default 15%)
Manoeuvre thrust activation
Increase the thrust torque during opening and closing.
F48 Manoeuvre thrust activation OFF (Default)
ON
RSE
Configure the function to be performed by the card inserted in the RSE connector.
F49 RSE OFF (Default)
1 = Paired
3 = CRP
Save data
Save user data, timings and configurations to the memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is inserted into the control board.
F50 Save data OFF (Default)
ON
Read data
Upload user data, timings and configurations from the memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is inserted into the control board.
F51 Read data OFF (Default)
ON