To correct the horizontal position:
- lift the boom;
- turn the mechanical closing stop clockwise to increase the boom travel or anticlockwise to decrease it .
Fasten the stop using a counter nut .
Establishing the limit-switch points
Close the inspection hatch and power the system. Activate the barrier to check whether the boom is parallel to the road surface when closed and
at about 89° when open.
The inspection hatch must be closed when the boom opens and closes.
To correct the vertical position of the boom:
- lower the boom;
- open the inspection hatch;
- turn the mechanical opening stop clockwise to increase the boom travel or anticlockwise to decrease it .
Fasten the stop using a counter nut .

Other manuals for CAME GARD 8 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME GARD 8 SERIES and is the answer not in the manual?

CAME GARD 8 SERIES Specifications

General IconGeneral
ModelGARD 8 SERIES
TypeAutomatic Barrier
Motor voltage24 V DC
Power300 W
Operating temperature-20°C to +55°C
Protection ratingIP54
Input Voltage230 V AC
Output Voltage24 V DC
Protection DegreeIP54
Power supply230 V AC
Opening time4 to 8 seconds

Related product manuals