To correct the horizontal position:
- lift the boom;
- turn the mechanical closing stop clockwise to increase the boom travel or anticlockwise to decrease it .
Fasten the stop using a counter nut .
Establishing the limit-switch points
Close the inspection hatch and power the system. Activate the barrier to check whether the boom is parallel to the road surface when closed and
at about 89° when open.
⚠
The inspection hatch must be closed when the boom opens and closes.
To correct the vertical position of the boom:
- lower the boom;
- open the inspection hatch;
- turn the mechanical opening stop clockwise to increase the boom travel or anticlockwise to decrease it .
Fasten the stop using a counter nut .