15 - Manual
FA00045-EN v.
2 - 09/2016- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Adjusting the trimmers
Trimmer
Description of functions
Sensitivity during slow-downs
Adjusts the amperometric sensitivity that controls the force exerted by the motor during slow-
downs; if the exerted force is greater than the setting, the system inverts the direction of travel.
Automatic Closing Time
Sets the open door's waiting time. Once this time elapses, a closing maneuver is automatically
performed.
The time can be set between 0 and 120 seconds.
Sets the time to a minimum, and excludes AUTOMATIC CLOSING.
Sensitivity during closing
Adjusts the amperometric sensitivity that controls the force exerted by the motor during closing;
if the exerted force is greater than the setting, the system inverts the direction of travel.
Sensitivity during opening
Adjusts the amperometric sensitivity that controls the force exerted by the motor during opening;
if the exerted force is greater than the setting, the system inverts the direction of travel.