Safety devices
A
(С1)
Contact (N.C.) for “re-opening during the closing”
Input for safety devices like photocells, sensitive edges and other devices that comply with EN 12978 regulations. While
the door is closing, opening the contact will invert movement until it is fully openend.
B
(СX)
Dip 8 OFF - 9 OFF
(Contact (N.C.) for “reclose while opening”
Input for safety devices like photocells, sensitive edges
and other devices that comply with EN 12978 regulations.
While the gate is closing, opening the contact will invert
movement until it is fully closed.
Dip 8 OFF - 9 ON
Contact (N.C.) for “partial stop”
Input for safety devices like photocells,
sensitive edges and other devices that comply
with EN 12978 regulations. Gate stops if
moving triggering automatic closing.
C
(TS)
Dip 13 ON
Safety test function
- At each open/close command, the card check the photocells’ e ciency. Any problems with the photocells will
cause the (8) Led to fl ash on the electronic card, which cancels any commands from the radio transmitter or push-
button.
IMPORTANT:
When the safety test function is activated, the N.C. contacts - if unused – are to be excluded on their relative DIP
switches (see chapter “selecting functions”).