LEFM 200 Modbus User Manual IB0147 Rev. 8
December 2010 Page 29 Section 4
4.3 Flow Data
Output Variable
Input Register
Variable
Definition
Address Units Notes
Flow (200 Series) Float 38 See HR52 &
HR54
Meter Factor Float 136 N/A
Totalizers
Output Variable
Input Register
Variable
Definition
Address Units Notes
Totalizer Number 1
(Resettable)
Float 140 See HR52
Totalizer Number 2
(not Resettable)
Float 142 See HR52
Totalizer (+) Float 144 See HR52
Totalizer (-) Float 146 See HR52
4.4 Analog Input Values
Output Variable
Input Register
Variable
Definition
Address Units Notes
Temperature, Body Float 78
See Holding Register
102 for units
Pressure Float 80
Temperature, Fluid Float 150
Density, Input Float 152