-49-
Maintenance 5
1. Open cutting blade shield.
2. Noting the direction of the at faces on
mounting pin, shift blade along mounting slot
to remove blade.
5331M-0508-050E
Mounting Slot
Flat Faces
3. Install new mounting pin to blade and
shift blade along mounting slot, noting the
direction of the at faces.
5331M-0508-060E
Blade
Mounting Pin
Always put thick gloves on and be cautious when handling blade because both
edges of rotor stay can get sharp by wear.
Wear Limit: See page 50
If it is difcult to remove blade, wash. (page 58)