Fuse
1. Remove fuse and visually inspect. If it is
blown, replace it with new one of the same
rating.
2. Install fuse back in place.
• If a fuse blows, investigate the cause before replacing.
• Always replace a fuse with one of the correct rating.
• Main Fuse: 15A.
• Replacement Fuse: Page 35.
NOTE
5. Remove ller caps.
6. Fill distilled water to "UPPER" level line.
7. Put ller caps back in place.
8. Install battery back in place.
9. Install positive (+) cable.
10. Install negative (-) cable.
11. Install mounting plate back in place.
12. Install front cover back in place.
1. Remove front cover.
2. Remove battery from machine.
3. Follow instructions in battery charger
operator's manual to charge battery.
4. When charge is complete, install battery to
machine.
5. Install front cover back in place.
Charging