8400-0181-OM Rev C 185 and 185B Installation & Technical
17
Unit1= (Weighing Unit 1)
Press the TARE key to view the current setting. To keep the current setting, press the
TARE key again. Otherwise, press the Fn/
▲
key to scroll through the available values.
When the desired value is displayed, press the TARE key to select the displayed value
and proceed to the next prompt.
Available values are:
1 = lb (Pounds) 2 = kg (Kilograms) 3 = oz (ounces) 4 = g (Grams)
Int= (Interval Setting)
Press the TARE key to view the current setting. To keep the current setting, press the
TARE key again. Otherwise, press the Fn/
▲
key to scroll through the available values.
When the desired value is displayed, press the TARE key to select the displayed value
and proceed to the next prompt.
Available values are 1, 2, 5, 10, 20, or 50.
dPP= (Decimal Point Position)
Press the TARE key to view the current setting. To keep the current setting, press the
TARE key again. Otherwise, press the Fn/▲ key to scroll through the available values.
When the desired value is displayed, press the TARE key to select the displayed value
and proceed to the next prompt.
Available values are:
0 = XXXXXX 1= XXXXX.X 2 = XXXX.XX 3 = XXX.XXX
CAP= (Capacity)
Press the TARE key to view the current setting. To keep the current setting, press the
TARE key again. Otherwise, use the Fn/ and UNITS/ keys to enter a new value. When
the desired value is displayed, the TARE key to select the displayed value and proceed to
the next prompt.
Available values are 1 through 999999.
Unit2= (Weighing Unit 2)
Press the TARE key to view the current setting. To keep the current setting, press the
TARE key again. Otherwise, press the Fn/▲ key to scroll through the available values.
When the desired value is displayed, press the TARE key to select the displayed value
and proceed to the next prompt.
Available values are:
0 = Disabled 1 = lb (Pounds) 2 = kg (Kilograms) 3 = oz (ounces) 4 = g (Grams)
NOTE: The selection for Unit2 cannot be the same as Unit1. In addition, for
some settings of int (interval) and dpp (decimal point position), not all unit
combinations are available.