8555-M210-O1 Rev R 758C Owner’s 28
SETUP AND CALIBRATION, CONT.
btn= (BUTTON OPERATION)
This setting determines which keys (NET/GROSS, TARE, and/or ID/HEIGHT) are locked out
during normal operation.
Press PRINT/ENTER key to show current setting. If value displayed is acceptable, press
PRINT/ENTER key to save it. Otherwise using numeric keys, enter a new value and then
press PRINT/ENTER key to save it. Allowable values are 0, 1, 2 or 3.
0 = No Keys Disabled 2 = ID/HEIGHT Keys Disabled
1 = NET/GROSS and TARE Keys
Disabled
3 = NET/GROSS, TARE, and
ID/HEIGHT Keys Disabled
niCAd (BATTERY TYPE SELECTION)
This setting determines whether Alkaline, NiCad (or NiMH) batteries are used for battery
operation.
With display showing niCAd=, press PRINT/ENTER key to show current setting. If setting
displayed is acceptable, press PRINT/ENTER key to save it. Otherwise use numeric keys
0/NO or 1/YES and enter a new setting. Press PRINT/ENTER key to save it.
0 = Alkaline 1 = NiCad or NiMH
PUO= (POWER UP ZERO)
With display showing PUO=, press PRINT/ENTER key to show current setting. If setting
displayed is acceptable, press PRINT/ENTER key to save it. Otherwise use numeric keys
0/NO or 1/YES and enter a new setting. Press PRINT/ENTER key to save it and proceed to
the next prompt. Allowable values are 0 or 1.
0 = NO (Weight display will not be
reset to zero)
1 = YES (Weight display will be reset
to zero automatically on power up)
ASH= (AUTOMATIC SHUTOFF)
The Automatic Shutoff feature will turn the indicator off after a period of approximately 1 to 9
minutes of inactivity to prolong battery life. You must press ON/OFF key to turn indicator
back on.
With display showing ASH=, press PRINT/ENTER key to show current setting. If setting
displayed is acceptable, press PRINT/ENTER key to save it. Otherwise use numeric keys to
enter a new setting and then press PRINT/ENTER key to save it. Allowable values are 0
through 9 with 0 disabling Automatic Shutoff.
SLP= (SLEEP MODE)
The Sleep Mode feature also conserves battery power when the indicator remains unused for
a period of approximately 1 to 9 minutes. When enabled, the load cell excitation will be
reduced and the display will show SLEEP. The Sleep feature requires the indicator to remain
at the center of zero to activate, unlike Automatic Shutoff feature which only requires no
motion. Weight placed on scale will activate indicator and return it to weight mode.
With display showing SLP=, press PRINT/ENTER key to show current setting. If setting
displayed is acceptable, press PRINT/ENTER key to save it. Otherwise using numeric keys,
enter a new setting and then press PRINT/ENTER key to save it. Allowable values are 0
through 9 with 0 disabling Sleep Mode