Hardware Guide for the
DRX-Revolution Nano Mobile X-ray System
Publication No. AF0118
2018-03-27
Supersedes:
2018-01-22

Other manuals for Carestream DRX-Revolution

Questions and Answers

Summary

Overview

Safe Operation Precautions

Stresses reading precautions and observing warnings for safe operation.

Product Description

Power

Explains how the system operates on rechargeable batteries.

Mobility

Describes the low-profile arm and transport system for maneuverability.

Main Battery Charging

Outlines the process and time for charging the main battery bank.

Operator Interface

Lists components of the user interface like monitor and scanners.

Diagnostics

Explains diagnostic screens and service history logging.

PC Controller

Details the specifications of the system's PC controller.

Supported Detectors

Lists the compatible detectors for the system.

Operation and Use

Cart Maneuverability and Positioning

Explains how to move and position the cart using its brakes.

Arm and Tube Head Assembly

Describes the structure and function of the arm assembly.

Exposure Factors and the X-ray Tube

Details X-ray tube technology, voltage, and exposure timing.

Time Cycle between Exposures

Explains the cool-down periods between X-ray exposures.

Component Descriptions

Provides detailed descriptions of various system components.

Touchscreen Monitor

Details the functions and display of the touchscreen.

X-ray Tube

Provides specifications for the X-ray tube, including focal spots.

Operating the System

Drive the Cart

Provides instructions on how to safely drive the system cart.

Dock and Deploy the Arm

Explains the procedure for docking and deploying the arm.

Power Button Operation

Explains the functionality of the system's power button.

Maintenance and Safety Information

System Maintenance

Outlines general maintenance requirements and responsibilities.

Replacing the Batteries

Information on battery replacement schedule and procedure.

General Safety Information

Broad safety guidelines and warnings for system use.

Technical Specifications

Cart

Lists specifications for the cart, including weight and speed.

Tube Head Assembly

Details movement and holding forces for the tube head assembly.

Troubleshooting

System Startup Issues

Troubleshooting steps for system startup issues.

Service and Support

Contact information for technical support and service.

Carestream DRX-Revolution Specifications

General IconGeneral
Display19-inch touchscreen
TypeMobile X-ray System
Generator Power32 kW
Tube Focal Spot0.6/1.2 mm
Dynamic Range14 bits
Battery LifeUp to 8 hours
Detector Size35 cm x 43 cm (14 in x 17 in)
BatteryRechargeable lithium-ion
MobilityMotorized
ConnectivityWireless
kV Range40 to 150 kV
mA Range10 to 400 mA
Pixel Pitch139 µm
CompatibilityDICOM compliant
Environmental ConditionsOperating Temperature: 10°C to 35°C (50°F to 95°F); Humidity: 30% to 75% non-condensing
Detector TypeWireless

Related product manuals