Error no.
Possible causes Possible error correction
79
Faulty definition of shift times
(overlapping times).
Check definition of shift times.
80 RSS bar code error.
Check definition and parameter of RSS
bar code.
81 RSS bar code error. Check sent data.
82
Printing creation was still active at print
start.
Reduce print speed.
Use printers' output signal for
synchronisation.
Use bitmap fonts to reduce generating
time.
83 RSS bar code error.
Displace zero point sensors.
Check sensors in service functions
menu.
84 No font data available. Execute a software update.