Motor Controllers AC Variable Frequency Drives Type VariFlex
3
RVLF
Group 07 Start/Stop command setup
No. Description Range
Factory
setting
Unit
Note
07-00
Momentary power loss and restart
0: Momentary power loss and restart disable
1: Momentary power loss and restart enable
0 -
07-01
Auto restart delay time
0.0~800.0 0.0 s
07-02
Number of auto restart attempts 0~10 0 -
07-03
Reset mode setting
0: Enable reset only when run command is Off
1: Enable reset when run ommand is On or Off
0 -
07-04
Direct running after power Up
0: Enable direct run on power up
1: Disable direct run on power up
1 -
07-05
Delay-ON timer 1.0~300.0 1.0 s
07-06
DC injection brake start frequency (Hz)
in stop mode
0.10~10.00 1.5 Hz
07-07
DC injection brake level (%) in stop
mode
0~20 5 %
07-08
DC injection brake time (seconds)
In stop mode
0.0~25.5 0.5 s
07-09
Stopping method
0: Deceleration to stop
1: Coast to stop
0
07-10
DC Braking Level at Start 0~100 0 %
07-11
DC Braking time at Start 0.0~25.5 0 %
Group 06 Auto run (Auto Sequencer) function
No. Description Range
Factory
setting
Unit
Note
06-34
Auto Run mode running direction 2
0: Stop
1: Forward
2: Reverse
0 -
06-35
Auto Run mode running direction 3
0 -
06-36
Auto Run mode running direction 4
0 -
06-37
Auto Run mode running direction 5
0 -
06-38
Auto Run mode running direction 6
0 -
06-39
Auto Run mode running direction 7
0 -
52 Specications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017