Page | 52
‘Holes’ in the point cloud
Cause
Remedy
Reference in manual
Standing water or very unreflective
surfaces such as coal are present.
Laser ranging to wet or very dark
surfaces is unpredictable. Try
moving closer to the targeted
surfaces.
Section 7.1, “System limitations
Surfaces are beyond the range of
the laser.
Set up the Quarryman Pro in
another location if possible and
combine scans to overcome range
limitations.
Section 7.1, “System limitations
Dark surfaces in the scan. Surfaces such as coal can give
severely reduced ranges. Move
closer to the target.
Section 7.1, “System limitations
Point cloud is ill-defined and ‘fuzzy
Cause
Remedy
Reference in manual
Thick dust, mist or snow interfering
with the scan.
Switch on last-hit mode. If the
problem persists, wait for dust or
bad weather to clear, if feasible.
Section 6.3, “Main menu”
Standing water, running water or
wet surfaces present.
None. Laser ranging to wet
surfaces is unpredictable.
Section 7.1, “System limitations
9.2 Other faults
If you are not able to repair or pinpoint a fault from the table above, you should contact the product support
department at Carlson, or your local Carlson representative for further assistance.