62-11648 26
13. Start-Stop or Continuous Operation
1. With the system powered up (START/RUN-OFF switch in the START/
RUN position) press the START-STOP/CONTINUOUS key until the
desired operation (Start/Stop or Continuous) is highlighted.
2. The message (“START/STOP MODE SELECTED” or “CONTINUOUS
RUN MODE SELECTED”) will be displayed in the MessageCenter for 10
seconds.
3. The operation indication in the status bar will no longer be highlighted. The
unit is now in the displayed mode.
NOTE
If the message “CONTINUOUS LOCKED” or “START/STOP
LOCKED” is displayed, the system is currently locked into the
displayed mode of operation and cannot be changed using the
“START/STOP - CONTINUOUS” key.
Start-Stop is provided to reduce fuel or power consumption. This feature
allows full automatic control of unit shut down and restart by monitoring
compartment temperature, battery charge condition, and when in Engine
Operation, coolant temperature. The main function of Start-Stop Operation is
to turn off the refrigeration system near setpoint to provide an efficient
temperature control system and to initiate a restart sequence after certain
conditions are met.
START/STOP DIESEL
BOX
SETPOINT
START/STOP MODE SELECTED
o
F
TEMP
-10
28.1 36.2
28
COOL COOL
36
-9.9
COOL
1 & 3
1
2