EasyManua.ls Logo

Carrier TRANSICOLD Vector 8600MT - Adjusting Temperature Setpoints; Modifying Setpoint Values

Carrier TRANSICOLD Vector 8600MT
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62-11648 24
12. Changing Setpoint
Individual compartment control status and temperature display boxes are
configured left to right to match the compartments in the trailer, front to back.
The left display box shows the status of the first compartment (C1), the middle
display box shows the status of the second compartment (C2), and the right
display box shows the status of the third compartment (C3). In a two-
compartment configuration, the right display box is blank.
1. With the system powered up (START/RUN-OFF switch in the START/
RUN position) and the default screen displayed (press the BACK or EXIT
soft key if required).
2. Press the or key to bring the displayed setpoint to the desired value.
Compartment 1 Compartment 2 Compartment 3
Temp 9.9
Cool Mode
Setpoint -10
Temp 28.1
Cool Mode
Setpoint 28
Temp 36.2
Cool Mode
Setpoint 36
START/STOP DIESEL
BOX
SETPOINT
STATUS OK
o
F
TEMP
-10
28.1 36.2
28
COOL COOL
36
-9.9
COOL
2
3