EasyManuals Logo

Carrier 40GVM Series User Manual

Carrier 40GVM Series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
27
FUNCTION AND CONTROLS CONTINUED
The “TIMER OFF” time will be stored in memory indefinitely
until is is cancelled by pushing the the “TIMER OFF” button or
the batteries are replaced in the remote control.
If the unit is running and the “TIMER OFF” set time is reached,
the unit will turn off and the operation indicator light on the front
panel will turn red. The display on the remote control will remain
the same as when the unit was running. To turn the unit on again,
push the “ON/OFF” button twice. The operation indicator light on
the front panel will turn green.
Timer ON and Timer OFF
º
F
º
C
HOUR
:
OPER
ON/OFF will
be displayed
ON/OFF
A09643
Use both functions as described in “TIMER ON” and TIMER
OFF” sections to program the unit to turn on and shut off at
specified times. Times will be stored in memory until cancelled
by user or the remote control batteries are replaced.
Light
Function
This function will allow the user to Turn ON or OFF the display
on the front panel.
Press the light icon
to turn the indoor unit front panel ON or
OFF. The remote control will display the Light Icon as shown
below.
Light Icon
A12435
Time Delay
If the On/Off button is pressed too soon after a stop, the
compressor will not start for 3 minutes due to the inherent
protection against frequent compressor cycling. The unit will only
emit an audible beep when the signals are received correctly.
Heating Featur
es
If the unit is in the heating mode, there will be a delay when the
fan starts. The fan will start only after the coil is warmed up to
prevent cold blow.
Defrost
Operation
In heating mode, if the outdoor coil is frosted, the indoor fan and
outdoor fan will turn off while system removes the frost on the
outdoor coil. “H1” will be displayed on the display panel on the
front cover of the unit.
The system will automatically revert to normal operation when
frost is removed from the outdoor unit, and “H1” will disappear.
Auto
Start
If the power fails while the unit is operating, the unit stores the
operating condition, and it will start operation automatically under
those conditions when the power is restored.

Table of Contents

Other manuals for Carrier 40GVM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 40GVM Series and is the answer not in the manual?

Carrier 40GVM Series Specifications

General IconGeneral
BrandCarrier
Model40GVM Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals