Fig. 7 — 42CE Horizontal Furred-In With Plenum Unit Dimensions
UNIT
SIZE
42CE
DIMENSIONS in. [mm]
a,b,c,d,e,f,g,h,i,j
NOTE(S):
a. Right-hand units shown, left-hand opposite.
b. All dimensions are ± .25 [6]. Drawing not to scale.
c. Product specifications are subject to change without notice.
d. Drip lip recommended. Provided when valve package is ordered.
e. Control box size and position may vary. Consult factory.
f. Position may vary.
g. Service entrance is located on the rear of the control box with knockouts.
h. Units without service switch use the knockouts on the rear side of the control box.
i. Typical size 06 unit shown with 1-Motor and 2-Blower. Refer to table for variation.
j. See valve package supplemental for piping termination.
QTY/UNIT
A B C E F G H K L Blower Motor
02 21-1/4 [540] 28-1/2 [724] 16 [406] 18-1/4 [464] 6-1/4 [159] 8-3/4 [222] 19-3/4 [502] 15-3/8 [391] 18-1/4 [464] 1 1
03 25-1/4 [641] 32-1/2 [826] 20 [508] 22-1/4 [565] 6-1/4 [159] 8-3/4 [222] 23-3/4 [603] 19-3/8 [493] 22-1/4 [565] 1 1
04 31-1/4 [794] 38-1/2 [978] 26 [660] 28-1/4 [718] 6-1/4 [159] 8-3/4 [222] 29-3/4 [756] 25-3/8 [654] 28-1/4 [718] 2 1
06 36-1/4 [921] 43-1/2 [1105] 31 [787] 33-1/4 [845] 7-1/2 [191] 10 [254] 34-3/4 [883] 30-3/8 [772] 33-1/4 [845] 2 1
08 43-1/4 [1099] 50-1/2 [1283] 38 [965] 40-1/4 [1022] 7-1/2 [191] 10 [254] 41-3/4 [1060] 37-3/8 [950] 40-1/4 [1022] 2 1
10 57-1/4 [1454] 64-1/2 [1638] 52 [1321] 54-1/4 [1378] 7-1/2 [191] 10 [254] 55-3/4 [1416] 51-3/8 [1306] 54-1/4 [1378] 4 2
12 65-1/4 [1657] 72-1/2 [1842] 60 [1524] 62-1/4 [1581] 7-1/2 [191] 10 [254] 63-3/4 [1619] 59-3/8 [1509] 62-1/4 [1581] 4 2
K
Rear Mtg. Holes
Unit Label and
Wiring Diagram
(See Note f)
6
[152]
Max.
Optional
Service
Switch
(Underneath)
15 [382]
See Note
e,g,h
1-1/2
[381]
1-1/4
[32]
2-1/4
[58]
E
Mounting Holes
C
A
Drain Pan No Valve Pkg
Top View
2-3/4
[71]
7/8 [22]
O.D.
Condensate
Drain
2
[51]
3/4
[19]
Typ
H
Front View
Chilled/Hot Water
Supply and Return
Connections
(See Detail A)
14-1/8
[360]
Optional Drip Lip
Mounting Location
No Valve Pkg
Shipped Loose
(See Note d)
Right Side View
Return
Air
Filter
Removal
Rear Access
Panel
Optional Return
Air Location
F
G
Supply
Air
3/4
[20]
1” [25] Supply
Duct Collar
20-1/8
[510]
19
[485]
11-1/4
[288]
B
Drain Pan with Valve Pkg
(Broken View)
*For other drain pan options see supplement.
21-9/16
[548]
Drip Lip with
Valve Pkg
Shipped Loose
(See Note d)
5-1/2
[141]
4-1/8
[106]
2-3/4
[71]
4-1/4
[108]
2-1/8
[53]
1
[25]
Detail A
Coil Stub Out
Locations for
Standard Coils
L
Rear/Bottom Return
LEGEND
CR — Cold Water Return
HR — Hot Water Return
CS — Cold Water Supply
HS — Hot Water Supply
10-1/2
[266]

Table of Contents