Fig. 8 — 42CE Horizontal Furred-In With Plenum and Side Filter Access Unit Dimensions
L
K
Rear/Bottom Return
Rear Mtg. Holes
6
[153]
Max.
Filter Removal
Both Sides
Optional
Service
Switch
(underneath)
15 [382]
See
Note e,g,h
1-1/2
[38]
1-1/4
[32]
2-1/4
[58]
E
C
A
Mounting Holes
Drain Pan No Valve Pkg
Top View
Unit Label and
Wiring Diagram
(See Note f)
Resilient Mounting
Grommet with 3/8 [10]
Dia. Holes (Typ. of 4)
2
[51]
7/8 [22]
O.D. Condensate
Drain
2-3/4
[71]
H
3/4
[19]
Typ
Chilled/Hot Water
Supply and Return
Connections
See Detail A
14-1/8
[360]
Optional Drip Lip
Mounting Location
No Valve Pkg
Shipped Loose
(See Note d)
Front View
Drip Lip
with Valve Pkg
Shipped loose
(See Note d)
21-9/16
[548]
B
Drain Pan with Valve Pkg
(Broken View)
*For other drain pan options see supplement.
4-1/4
[108]
2-1/8
[53]
1
[25]
2-3/4
[71]
4-1/8
[106]
5-1/2
[141]
Detail A
Coil Stub Out
Locations for
Standard Coils
20-1/8
[510]
19
[485]
1" [25] Supply
Duct Collar
3/4
[20]
Supply
Air
F
G
12
[303]
Return Air
Location
10-3/4
[271]
Right Side View
LEGEND
CR — Cold Water Return
HR — Hot Water Return
CS — Cold Water Supply
HS — Hot Water Supply
UNIT
SIZE
42CE
DIMENSIONS in. [mm]
a,b,c,d,e,f,g,h,i,j
NOTE(S):
a. Right-hand units shown, left-hand opposite.
b. All dimensions are ± .25 [6]. Drawing not to scale.
c. Product specifications are subject to change without notice.
d. Drip lip recommended. Provided when valve package is ordered.
e. Control box size and position may vary. Consult factory.
f. Position may vary.
g. Service entrance is located on the rear of the control box with knockouts.
h. Units without service switch use the knockouts on the rear side of the control box.
i. Typical size 06 unit shown with 1-Motor and 2-Blower. Refer to table for variation.
j. See valve package supplemental for piping termination.
QTY/UNIT
A B C E F G H K L Blower Motor
02 21-1/4 [540] 28-1/2 [724] 16 [406] 18-1/4 [464] 6-1/4 [159] 8-3/4 [222] 19-3/4 [502] 15-3/8 [391] 18-1/4 [464] 1 1
03 25-1/4 [641] 32-1/2 [826] 20 [508] 22-1/4 [565] 6-1/4 [159] 8-3/4 [222] 23-3/4 [603] 19-3/8 [493] 22-1/4 [565] 1 1
04 31-1/4 [794] 38-1/2 [978] 26 [660] 28-1/4 [718] 6-1/4 [159] 8-3/4 [222] 29-3/4 [756] 25-3/8 [654] 28-1/4 [718] 2 1
06 36-1/4 [921] 43-1/2 [1105] 31 [787] 33-1/4 [845] 7-1/2 [191] 10 [254] 34-3/4 [883] 30-3/8 [772] 33-1/4 [845] 2 1
08 43-1/4 [1099] 50-1/2 [1283] 38 [965] 40-1/4 [1022] 7-1/2 [191] 10 [254] 41-3/4 [1060] 37-3/8 [950] 40-1/4 [1022] 2 1
10 57-1/4 [1454] 64-1/2 [1638] 52 [1321] 54-1/4 [1378] 7-1/2 [191] 10 [254] 55-3/4 [1416] 51-3/8 [1306] 54-1/4 [1378] 4 2
12 65-1/4 [1657] 72-1/2 [1842] 60 [1524] 62-1/4 [1581] 7-1/2 [191] 10 [254] 63-3/4 [1619] 59-3/8 [1509] 62-1/4 [1581] 4 2