Fig. 9 — 42CE Horizontal Furred-In With Plenum With Electric Heat Unit Dimensions
UNIT
SIZE
42CE
DIMENSIONS in. [mm]
a,b,c,d,e,f,g,h,i,j
NOTE(S):
a. Right-hand units shown, left-hand opposite.
b. All dimensions are ± .25 [6]. Drawing not to scale.
c. Product specifications are subject to change without notice.
d. Drip lip recommended. Provided when valve package is ordered.
e. Control box size and position may vary. Consult factory.
f. Position may vary.
g. Service entrance is located on the rear of the control box with knockouts.
h. Units without service switch use the knockouts on the rear side of the control box.
i. Typical size 06 unit shown with 1-Motor and 2-Blower. Refer to table for variation.
j. See valve package supplemental for piping termination.
QTY/UNIT
A BCE FG H K LBlowerMotor
02 21-1/4 [540] 28-1/2 [724] 16 [406] 18-1/4 [464] 6-1/4 [159] 8-3/4 [222] 19-3/4 [502] 15-3/8 [391] 18-1/4 [464] 1 1
03 25-1/4 [641] 32-1/2 [826] 20 [508] 22-1/4 [565] 6-1/4 [159] 8-3/4 [222] 23-3/4 [603] 19-3/8 [493] 22-1/4 [565] 1 1
04 31-1/4 [794] 38-1/2 [978] 26 [660] 28-1/4 [718] 6-1/4 [159] 8-3/4 [222] 29-3/4 [756] 25-3/8 [654] 28-1/4 [718] 2 1
06 36-1/4 [921] 43-1/2 [1105] 31 [787] 33-1/4 [845] 7-1/2 [191] 10 [254] 34-3/4 [883] 30-3/8 [772] 33-1/4 [845] 2 1
08 43-1/4 [1099] 50-1/2 [1283] 38 [965] 40-1/4 [1022] 7-1/2 [191] 10 [254] 41-3/4 [1060] 37-3/8 [950] 40-1/4 [1022] 2 1
10 57-1/4 [1454] 64-1/2 [1638] 52 [1321] 54-1/4 [1378] 7-1/2 [191] 10 [254] 55-3/4 [1416] 51-3/8 [1306] 54-1/4 [1378] 4 2
12 65-1/4 [1657] 72-1/2 [1842] 60 [1524] 62-1/4 [1581] 7-1/2 [191] 10 [254] 63-3/4 [1619] 59-3/8 [1509] 62-1/4 [1581] 4 2
L
Rear/Bottom Return
K
Rear Mtg. Hole
6-1/4
[160]
Max.
Optional
Service
Switch
(Underneath)
19.13
[486]
See Note
e,g,h
1-1/2
[38]
1-1/4
[32]
2-1/4
[57]
E
C
A
Mounting Holes
Drain Pan No Valve Pkg
2-3/4
[71]
7/8 [22]
O.D.
Condensate
Drain
2
[51]
Electric Strip
Heater Element
Strip Heater
High Limit
Resilient Mounting
Grommet with 3/8 [10]
Dia. Holes (Typ. of 4)
Unit Label and Wiring
Diagram (See Note f)
Top View
Front View
H
3/4
[19]
Typ.
14-1/8
[360]
Chilled/Hot Water
Supply and Return
Connections
(See Detail A)
Optional Drip Lip
Mounting Location
No Valve Pkg
(Shipped Loose)
(See Note d)
Right Side View
Return
Air
Filter
Removal
11-1/4
[287]
Rear
Access
Panel
10-1/2
[265]
Optional
Return Air
Location
24-3/16
[614]
23-1/4
[589]
1" [25] Supply
Duct Collar
3/4
[201]
Detail A - Stub Out
Locations for
Standard Coils
Drip Lip With
Valve Pkg
(Shipped Loose)
(See Note d)
21-9/16
[548]
B
Drain Pan With Valve Pkg
(Broken View)
*For other drain pan options see supplement.
4-1/4
[108]
2-1/8
[53]
4-1/8
[106]
Supply
Air
G
F
LEGEND
CR — Cold Water Return
HR — Hot Water Return
CS — Cold Water Supply
HS — Hot Water Supply