16
Fig. 11 — 42CE Horizontal Furred-In With Plenum, Same Side Piping, and Controls Unit Dimensions
Resilient Mounting
Gromment with 3/8 [10]
Dia. Holes (Typ. of 4)
Unit Label and Wiring
Diagram
(See Note f)
15 [382]
1-1/2
[38]
L
K
Rear/Bottom Return
Rear Mtg. Holes
5-1/2
[141]
Max.
Optional
Service
Switch
See Notes e,g,h
7/8 [22]
O.D.
Condensate
Drain
2
[51]
15/16
[24]
C
E
Mounting Holes
A
Drain Pan With Valve Pkg
1-1/4
[32]
2-1/4
[57]
Top View
Front View
Right Side View
Chilled/Hot Water
Supply and Return
Connections
See Detail A
3/4
[19]
Typ
H
11-1/4
[288]
Rear Access
Panel
10-1/2
[266]
Optional
Return Air
Location
Return
Air
Filter
Removal
Supply
Air
G
3/4
[20]
1" [25] Supply
Duct Collar
20-1/8
[510]
19
[485]
F
Detail A
Coil Stub Out Locations
(Dimensions shown are for any coil.)
LEGEND
4-1/4
[108]
2-1/8
[53]
1
[25]
2-3/4
[71]
4-1/8
[106]
5-1/2
[141]
CR — Cold Water Return
HR — Hot Water Return
CS — Cold Water Supply
HS — Hot Water Supply
Drain Pan Without Valve Package
B
UNIT
SIZE
42CE
DIMENSIONS (in.)
a,b,c,d,e,f,g,h,i,j
NOTE(S):
a. Right-hand units shown, left-hand opposite.
b. All dimensions are ± .25 [6]. Drawing not to scale.
c. Product specifications are subject to change without notice.
d. Drip lip recommended. Provided when valve package is ordered.
e. Control box size and position may vary. Consult factory.
f. Position may vary.
g. Service entrance is located on the rear of the control box with knockouts.
h. Units without service switch use the knockouts on the rear side of the control box.
i. Typical size 06 unit shown with 1-Motor and 2-Blower. Refer to table for variation.
j. See valve package supplemental for piping termination.
QTY/UNIT
ABCDEFHBlowerMotor
02 35 [889] 16 [406] 12-3/4 [324] 37 [940] 32 [813] 6 [152] 18-3/4 [476] 1 1
03 35 [889] 20 [508] 8-3/4 [225] 37 [940] 32 [813] 6 [152] 18-3/4 [476] 1 1
04 41 [1041] 26 [660] 8-3/4 [225] 43 [1092] 38 [965] 6 [152] 24-3/4 [629] 2 1
06 53 [1346] 31 [787] 15-3/4 [400] 55 [1397] 50 [1270] 7 [179] 35-3/4 [908] 2 1
08 53 [1346] 38 [965] 8-3/4 [225] 55 [1397] 50 [1270] 7 [179] 35-3/4 [908] 2 1
10 75 [1905] 52 [1321] 16-3/4 [425] 77 [1829] 72 [1829] 7 [179] 49-3/4 [1264 4 2
12 75 [1905] 60 [1524] 8-3/4 [225] 77 [1829] 72 [1829] 7 [179] 49-3/4 [1264] 4 2