Model Size
060-14
080-14
060-20
080-20
100-22
120-22
NOMINAL AIRFLOW BASED ON 350 CFM/TON (Factory Default - SW1-5 = OFF, SW4-3 = OFF)
SW2 Clg Default SW3 CF Default COOLING (SW2) AND CONTINUOUS FAN (SW3) AIRFLOW: SET-UP SWITCH POSITIONS
33 2 1N
1050
1050
1750
1750
1750
1750
2 1 N
525
525
700
700
700
875
3 2 1 N
525
525
700
700
700
700
3 2 I N
700
700
875
875
875
875
3 2 1N
875
875
1050
1050
1050
1050
3 2 1N
1050
1050
1225
1225
1225
1225
3 2 1 N
1225
1225
1400
1400
1400
1400
3 2 1N 3 2 1N
1225 1225
1225 1225
1750 1750
1750 1750
1750 2100
1750 2100
NOMINAL AIRFLOW BASED ON 400 CFM/TON (SW1=5 = ON, SW4=3 = OFF)
SW3 CF Default COOLING (SW2) AND CONTINUOUS FAN (SW3) AIRFLOW: SET-UP SWITCH POSITIONS
Model Size
060-14
080-14
060-20
080-20
100-22
120-22
3 2 1N
600
600
800
800
800
1000
SW2 Dig DeDult
3 2 1 N
1200
1200
2000
2000
2000
2000
3 2 1N
60O
600
800
80O
80O
80O
3 2 I N
800
800
1000
1000
1000
1000
3 2 1N
1000
1000
1200
1200
1200
1200
3 2 1N
1200
1200
1400
1400
1400
1400
3 2 1N
1400
1400
1600
1600
1600
1600
3 2 1N
1400
1400
2000
2000
2000
2000
3 2 t N
1400
1400
2000
2000
2100
2100
NOMINAL AIRFLOW BASED ON 325 CFM/TON (SW1=5 = OFF, SW4=3 = ON)
SW3 CF Default COOLING (SW2) AND CONTINUOUS FAN (SW3) AIRFLOW: SET-UP SWITCH POSITIONS
Model Size
060-14
080-14
060-20
080-20
100-22
120-22
3 2 1N
488
488
651
651
651
814
SW2 CIg Default
3 2 1N
976
976
1627
1627
1627
1627
3 2 1N
488
488
651
651
651
651
3 2 1 N
651
651
814
814
814
814
3 2 1 N
814
814
976
976
976
976
3 2 1 N
976
976
1139
1139
1139
1139
3 2 1 N
1139
1139
1302
1302
1302
1302
3 2 1 N
1139
1139
1627
1627
1627
1627
3 2 1 N
1139
1139
1627
1627
1953
1953
NOMINAL AIRFLOW BASED ON 370 CFM/TON (SWI-5 = ON, SW4-3 = ON)
CF Default COOLING (SW2) AND CONTINUOUS FAN (SW3) AIRFLOW: SET-UP SWITCH POSITIONS
Model Size
060-14
080-14
06O-2O
080-20
100-22
120-22
SW2 Dig DeDult SW3
3 2 1N 3 2 1N 3 2 1N 3 2 I N 3 2 1N 3 2 1N 3 2 1N
1116 558 558 744 930 1116 1302
1116 558 558 744 930 1116 1302
1860 744 744 930 1116 1302 1488
1860 744 744 930 1116 1302 1488
1860 744 744 930 II16 1302 1488
1860 930 744 930 1116 1302 1488
Fig. 55 - Furnace Setup Switches and Description
3 2 1N
1302
1302
1860
1860
1860
1860
3 2 1 N
1302
1302
1860
1860
2100
2100
Al1623