March 2021 Page 66 of 143 59812-K007 Rev 17
Business Confidential
Use the Up and Down arrows to scroll through the events in this screen.
Figure 94 Event Log by Detector
screen, Figure 85.
3.7 DETECTOR SCREEN USER
In addition to information relating to the engine information can also be displayed for the individual
detectors.
Status information on a single engine can be accessed by pressing the required detector button under
the bar graph.
Figure 95 Detector Status Screen - User
The status screen shows:
Peak Level The highest oil mist level indicated by the detector since the peak level
was reset.
Alarm Level The slowdown/shutdown alarm level set for the detector.
Pre-Alarm Level The pre-alarm level set for the detector.
Isolated Indicates Yes if the detector is isolated.
Comms Fault Indicates Yes if the detector is not communicating with the Control Unit.
Fan Fault Indicates Yes if the fan has failed on the detector.
LED Fault Indicates Yes if there is oil contamination in the sample chamber.
Photodiode Fault Indicates Yes if light is failing to reach the measuring photodiode
Watchdog Fault Indicates Yes if a detector software failure has caused the detector to be
automatically reset.
Memory Fault Indicates Yes if a fault has been detected in the Control Unit memory