Figure 110 Engine Screen Pre-Alarm, Accept
Press Accept
Figure 111 Engine Screen Pre-Alarm, Accept
Prior to resetting the Engine, it is recommended that any additional events which may have occurred are
examined. A list of events can be shown by pressing the View Events button.
The alarm may be reset once the oil mist level falls below the pre-alarm level. The system will return
to the Engine Screen.
3.15 SLOWDOWN/SHUTDOWN ALARM OPERATION
If the oil mist level measured by a detector rises above the set slowdown/shutdown alarm level an
slowdown/shutdown alarm condition will be initiated. This is indicated by:
Detector Alarm LED on constant
Control Unit Activation of the Pre-Alarm and Slowdown/Shutdown
Relay
Control Unit with membrane Alarm indicator on constant
Operating Detector indicator flashing for the detector in
alarm.
Remote Display Unit Displays the Engine Overview Screen with the engine in
alarm displayed in red.