Fig. 25 - CHECKOUT MENU
A03204
The Checkout menu will show the equipment installed in the
system. A sample checkout menu is shown in Fig. 25.
CHECKOUT -- FURNACE OR GAS PAC
Make sure the furnace is properly installed before continuing.
• LOW HEAT RUNTIME: 5 min.
• HIG-H HEAT RUNTIME: 5 min.
This menu item allows the furnace to be exercised. First. a low
heat rnntime and high heat rnntime are selected. Range = 5 - 120
min.
If only the low heat is to be exercised:
The furnace will execute its ignition start-up sequence. This
sequence will be displayed on the Infinity Control screen. After
the gas valve and blower motor turn on, the screen will
automatically change to "FURNACE CHECK" and show the
current operating status of the furnace.
CHECKOUT--- ELECTRIC HEAT
• ELECTRIC HEAT RUNTIME: 5 min., Default time =
5 min., Range = 0 - 120 min.
If you have a fan coil with electric heaters, this menu item will
allow the heaters to be exercised.
With self-identifying electric heaters, three stages of electric heat
are available to be exercised in any combination. Non-identifying
heaters will only provide one stage of heat.
Enter the run time (in minutes) of each stage of heat to be
exercised then press START (right-side button). The display will
change to show the fan coil's operating status.
CHECKOUT -- HEAT PUMP HEATING
• HIGH HEAT RUNTIME: 5 min.
• LOW HEAT RUNTIME: 5 min.
• DEFROST: NO
The heat pump heating mode can be exercised with this menu
option. With a 2-stage heat pump, a low heat runtime and a high
heat runtime are independently selectable to exercise. A defrost
cycle is also selectable. Default time = Fixed 5 min. minimum,
range = 5 - 120 min.
NOTE: Airflows during Checkout modes are fixed to the
Efficiency setting and are independent of other airflow settings.
To view airflows for normal heat pump heating mode, exit the
Checkout screen and apply a heating demand to the system.
CHECKOUT -- HEAT PUMP COOLING OR AC
COOLING
• HIGH COOL RUNTIME: 5 min.
• LOW COOL RUNTIME: 5 min.
The heat pump cooling mode (or AC cooling mode) can be
exercised with this menu option. With a 2-stage heat pump or
AC unit, a low cool runtime and a high cool runtime are
independently selectable to exercise. The display ,,vill change to
show the heat pump or AC operating status.
Default time = Fixed 5 min. minimum, range = 5 - 120 rain.
NOTE: Airflows during Checkout modes are fixed to the
Efficiency setting and are independent of other airflow settings.
To view airflows for normal heat pump heating mode, exit the
Checkout screen and apply a heating demand to the system.
CHECKOUT -- HUMIDIFIER
• OFF
• ON
The humidifier can be exercised On and Off with this menu
option.
CHECKOUT -- VENTILATOR
SPEED:
OFF
LOW
HIGH
The ventilator can be exercised through all of its operating speeds
with this menu option.
CHECKOUT -- SYSTEM ACCESS MODULE (SAM)
RADIO CHECK:
This will perform a radio check of the SAM. Three messages will
be sent and received and can take up to 15 minutes to complete.
SAM RADIO CHECK SAM_ECK ]
CHECK CAN TAKE UP TO II
15 MINUTES MESSAGE 1 SENT
MESSAGE 1 RECEIVED
MESSAGE 2 SENT
MESSAGE 2 RECEIVED
3 MESSAGES WILL BE MESSAGE 3 SENT
SENT AND RECEIVED MESSAGE 3 RECEIVED
< RACK CONITIN_IF> < EACK I
d
Fig. 26 - SAM RADIO CHECK MENU
A04092
PROFILE UPDATE:
This will update the computer servers with the current equipment
configuration. If equipment changes, performing a Profile
Update will ensure the server has the latest system information.