HUMIDIFIER INSTALLED -- This will appear after the Air
Filter Type screen. Select whether a humidifier is installed on the
system, YES or NO, then press right-side button to continue.
UV LIGHTS INSTALLED -- This screen will appear to select
whether UV lights are installed on the system, select YES or NO,
then press right-side button to continue.
SECTION 5.--EQUIPMENT SUMMARY
IEQUIPMENT SUMMAR']
FURNACE 58MVP0100 12
AC 38TDBE3E0300
FILTER EAC
HUMIDIFIER YES
UV LIGHTS YES
< NO YES>
SETUP SAvECOMPLETEt I
ALL SELECTIONS?
< NO YES>
Fig. 19 - Equipment Summary
A04046
The "EQUIPMENT SUMMARY" screen will appear after
Accessories have been selected. This screen will give a sunmaary
of all equipment automatically found or manually selected. If a
wrong selection was made. press left-side button (BACK
selection) to go back to that particular screen and make changes.
When everything is OK, press right-side button again to
continue. (See Fig. 19)
The "SETUP COMPLETE! SAVE ALL SELECTIONS?" screen
will appear after Equipment Summary. To Save All Selections
press (YES) right-side button. Pressing the left-side button (NO
selection) will return to the Equipment Summary screen where
changes can be performed to any of the equipment selection
screens. After selecting YES, the initial power up sequence of the
new Infinity Control is complete.
SECTION &--STATIC PRESSURE CHECK
STATIC
PRESSURE
CHECK
PLEASE WAIT
EXTERNAL STATIC
PRESSURE
MEASURED:
072 INCHES
AT 1200 CFM
CONTINUE
Fig. 20 - STATIC PRESSURE CHECK
A05000
This screen will appear after Setup is exited. The system will
open all dampers and perform a static pressure check. This
process will take about 1 1/2 minutes to complete. When
completed, a screen will appear displaying the static pressure (in
inches) across the equipment at the expected highest delivered
airflow. If the static pressure is over 1 inch, a warning will
appear, but equipment operation and the TrueSense" dirty filter
detection operation will not be affected.
NOTE: The static pressure check occurs only at initial
installation, or when INSTALL is run in the INSTALL/SERVICE
menu.