7–39 T-362
7.28.4 Setting the Date and Time
1. Turn unit power off (“0”) at the Start-Stop switch (ST).
2. Inspect the pins on the controller’s programming slot for damage.
3. Insert the programming device (with proper software loaded) into the slot. See Figure 7.19.
4. Turn unit power on (“I”) at the Start-Stop switch (ST).
5. The display will show “Usb LOAd”. Use the Arrow keys to select "LOAd SoFt" and press the ENTER key.
The display will show "SEt UP"
.
NOTE
For PCMCIA sRAM cards, the display will show "SEt UP" when unit turns on.
6. Press the ENTER key on the keypad.
7. The display will show the message “ruN ConFG”.
8. Use the Arrow keys to display “SEt tIM” and then press ENTER.
9. The display will show the date in YYYY MM-DD format. The day value will be blinking.
10. The date values are modified from right to left. Use the Arrow keys to increase or decrease the values.
Press the ENTER key to confirm the value for the current field and move to the next value. Press the CODE
SELECT key to modify the previous value.
11. After pressing ENTER to confirm the year value, the time will be displayed in HH MM format with the hours
being in a 24 hour format. The minutes will be blinking.
12. The time values are modified from right to left. Use the Arrow keys to change the values. Press the ENTER
key to confirm the value for the current field and move to the next value. Press the CODE SELECT key to
modify the previous value.
13. After pressing ENTER to confirm the hour value, the display will return to “SEt tIM”.
14. Turn unit power off (“0”) at the Start-Stop switch (ST).
15. Remove the programming device from the controller.
16. Turn unit power on (“I”) at the Start-Stop switch (ST).
7.28.5 Setting the Container ID
NOTE
The characters will be preset to the container ID already on the controller. If none exist, the default will
be AAAA0000000.
1. Turn unit power off (“0”) at the Start-Stop switch (ST).
2. Inspect the pins on the controller’s programming slot for damage.
3. Insert the programming device (with proper software loaded) into the slot. See Figure 7.19.
4. Turn unit power on (“I”) at the Start-Stop switch (ST).
5. The display will show “Usb LOAd”. Use the Arrow keys to select "LOAd SoFt" and press the ENTER key.
The display will show "SEt UP"
.
NOTE
For PCMCIA sRAM cards, the display will show "SEt UP".
6. Press the ENTER key on the keypad.
7. The display will show the message “ruN ConFG”
8. Use the Arrow keys to display “SEt Id” and then press ENTER.
9. The display will show the first letter of the container ID.
10. Use the Arrow keys to change the values. Press ENTER to confirm a value for the current field and move to
the next value. Press the CODE SELECT key to modify a previous value.