T-362 3–12
3.3 Electrical Data
Table 3–2 Electrical Data
Circuit Breaker
CB-1 (25 amp) Trips at 29 amps
CB-2 (50 amp) Trips at 62.5 amps
CB-2 (70 amp) Trips at 87.5 amps
Compressor Motor (CP) Full Load Amps (FLA) 13 amps @ 460 VAC
Condenser Fan Motor
(CM)
Nominal Supply 380 VAC / 3 Phase / 50 Hz 460 VAC / 3 Phase / 60 Hz
Full Load Amps .71 amps .72 amps
Horsepower 0.21 hp 0.36 hp
Rotations Per Minute 1450 rpm 1750 rpm
Voltage and Frequency 360 - 460 VAC +/- 2.5 Hz 400 - 500 VAC +/- 2.5 Hz
Bearing Lubrication Factory lubricated, additional grease not required.
Rotation Counter-clockwise when viewed from shaft end.
Evaporator Coil Heaters
Number of Heaters 6
Rating 750 watts +5/-10% each @ 230 VAC
Resistance (cold) 66.8 to 77.2 ohms @ 20°C (68°F)
Type Sheath
Evaporator Fan Motors
(EM)
380 VAC / 3 Phase / 50 Hz 460 VAC / 3 Phase / 60 Hz
Full Load Amps
High Speed
1.07 .9
Full Load Amps
Low Speed
0.47 0.47
Nominal Horsepower
High Speed
0.36 0.63
Nominal Horsepower
Low Speed
0.05 0.8
Rotations Per Minute
High Speed
2850 rpm 3450 rpm
Rotations Per Minute
Low Speed
1425 rpm 1725 rpm
Voltage and Frequency 360 - 460 VAC +/- 1.25 Hz 400 - 500 VAC +/- 1.5 Hz
Bearing Lubrication Factory lubricated, additional grease not required
Rotation CW when viewed from shaft end
Fuses
Control Circuit 7.5 amps (F3A,F3B)
Controller / DataCORDER 5 amps (F1 & F2)
Emergency Bypass 10 amps (FEB)
Vent Position Sensor
(VPS)
Electrical Output 0.5 VDC to 4.5 VDC over 90 degree range
Supply Voltage 5 VDC +/- 10%
Supply Current 5 mA (typical)
Economizer Solenoid
Valve (ESV) Coils 24 VDC
Nominal Resistance @
77°F (25°C)
7.7 ohms +/- 5%
Maximum Current Draw 0.7 amps
Digital Unloader Valve
(DUV) Coils 12 VDC
Nominal Resistance @
77°F (20°C)
14.8 ohms +/- 5%
Maximum Current Draw 929 mA