T-362 4–52
Table 4–9 DataCORDER Function Code Assignments
Code Description
dC1 Recorder Supply Temperature
Current reading of the Supply Recorder Sensor (SRS).
dC2 Recorder Return Temperature
Current reading of the Return Recorder Sensor (RRS).
dC3-5 USDA 1,2,3 Temperatures
Current readings of the three USDA probes.
dC6-13 Network Data Points 1-8
Current values of the network data points (as configured). Data point 1 (Code 6) is generally the
humidity sensor and its value is obtained from the controller once every minute.
dC14 Cargo Probe 4 Temperature
Current reading of the cargo probe #4.
dC15-19 Future Expansion
These codes are for future expansion, and are not in use at this time.
dC20-24 Temperature Sensors 1-5 Calibration
Current calibration offset values for each of the five probes: supply, return, USDA #1, #2, and #3.
These values are entered via the interrogation program.
dC25-27 Future Expansion
These codes are for future expansion, and not in use at this time.
dC28 Minimum Days Left
An approximation of the number of logging days remaining until the DataCORDER starts to overwrite
the existing data.
dC29 Days Stored
Number of days of data that are currently stored in the DataCORDER.
dC30 Date of Last Trip Start
The date when a Trip Start was initiated by the user. In addition, if the system goes without power for
seven continuous days or longer, a Trip Start will automatically be generated on the next AC power
up. Press and hold “ENTER” key for five seconds to initiate a “Trip Start.”
dC31 Battery Test Results
Shows the current status of the optional battery pack.
PASS: Battery pack is fully charged. FAIL: Battery pack voltage is low.
dC32 Time: Hour, Minute
Current time on the real time clock (RTC) in the DataCORDER.
dC33 Date: Month, Day
Current date (month and day) on the RTC in the DataCORDER.
dC34 Date: Year
Current year on the RTC in the DataCORDER.
dC35 Cargo Probe 4 Calibration
Current calibration value for the Cargo Probe. This value is an input via the interrogation program.