4–49 T-362
Battery Low (battery pack)
Data Retrieval
Defrost Start and End
Dehumidification Start and End
Power Loss (with and without battery pack)
Power Up (with and without battery pack)
Remote Probe Temperatures in the Container (USDA Cold treatment and Cargo probe recording)
Return Air Temperature
Setpoint Change
Supply Air Temperature
Real Time Clock Battery (Internal) Replacement
Real Time Clock Modification
Trip Start
ISO Trip Header (When entered via Interrogation program)
Economy Mode Start and End
“Auto 1 / Auto 2 / Auto 3” Pre-Trip Start and End
Bulb Mode Start
Bulb Mode Changes
Bulb Mode End
USDA Trip Comment
Humidification Start and End
USDA Probe Calibration
Fresh Air Vent Position
4.6.2 DataCORDER Configuration Software
The configuration software controls the recording and alarm functions of the DataCORDER. Reprogramming to the
factory-installed configuration is achieved via a configuration card. Changes to the unit DataCORDER
configuration may be made using the DataLINE interrogation software.
A list of the configuration variables is provided in Table 4–7. Descriptions of DataCORDER operation for each
variable setting are provided in the following paragraphs.
Sensor Configuration (dCF02)
Two modes of operation may be configured: Standard Mode and Generic Mode.
Standard Mode
Table 4–7 DataCORDER Configuration Variables
Config Title Default Option
dCF01 (Future Use) -- --
dCF02 Sensor Configuration 2 2, 5, 6, 9, 54, 64, 94
dCF03 Logging Interval (Minutes) 60 15, 30, 60, 120
dCF04 Thermistor Format Short Long
dCF05 Thermistor Sampling Type A A, b, C
dCF06 Controlled Atmosphere / Humidity Sampling Type A A, b
dCF07 Alarm Configuration USDA Sensor 1 A Auto, On, Off
dCF08 Alarm Configuration USDA Sensor 2 A Auto, On, Off
dCF09 Alarm Configuration USDA Sensor 3 A Auto, On, Off
dCF10 Alarm Configuration Cargo Sensor A Auto, On, Off