62-11039 5-8
CONFIGURATION
SELECTIONS DESCRIPTION
ECONO MAX. TEMP
-- 1 9 °Fto+119°F
(--28.3°Cto
+48.3°C)
in 0.5°For°C
increments
Default: 119°F
(48.3°C)
OFF
Select the upper limit of the ambient range desired
for this parameter. See Section 4.6 for more infor-
mation on Econo Max. Temp.
ECONO DELTA--T
OFF
+3.6°F to +27.0°F
(+2°Cto 15°C)
in 0.5° Cor°Fin-
crements
Select the desired Delta--T value for activation of
ProductShield Econo: Go To S/S
This parameter is not available for Econo: Go To
Continuous Run
PRODUCTSHIELD HIGH AIR
OFF
ON
OFF = The unit will operate normally in high and
low speeds.
ON = The unit will operate in high speed when the
ambient air temperature falls OUTSIDE the mini-
mum / maximum temperature range (selected set-
tings for HIGH AIR MIN TEMP, HIGH AIR MAX
TEMP, AND HIGH AIR DELTA--T -- see below)
HIGH AIR MIN. TEMP
-- 1 9 °Fto+119°F
(--28.3°Cto
+48.3°C)
in 0.5°For°C
increments
Default: 119°F
(48.3°C)
OFF
Select the lower limit of the ambient range desired
for this parameter. See Section 4.6 for more infor-
mation on High Air Min. Temp.
HIGH AIR MAX. TEMP
-- 1 9 °Fto+119°F
(--28.3°Cto
+48.3°C)
in 0.5°For°C
increments
Default: 119°F
(48.3°C)
OFF
Select the upper limit of the ambient range desired
for this parameter. See Section 4.6 for more infor-
mation on Econo Max. Temp.
HIGH AIR DELTA--T
OFF
+3.6° F to +27.0°F
(+2°Cto 15°C)
in 0.5° Cor°Fin-
crements
Select the desired Delta--T value for activation of
ProductShield High Air
PRODUCTSHIELD WINTER
OFF
-- 2 0 °F to +32.0°F
(--28.9°Cto 0°C)
in 0.5° Cor°Fin-
crements
Select the desired ambient temperature for activa-
tion of installed ProductShield Winter. When ambi-
ent temperature falls below this selected value, the
unit will run in Continuous Run only. See Section
4.6 for more information on ProductShield Winter.
RANGE (1--2) LOCK
COMPARTMENT 1 ONLY
OFF
START--STOP
CONTINUOUS
OFF = If both Range 1 & Range 2 Locks are off,
Start--Stop or Continuous Run may be selected.
If either Range 1 or Range 2 is not OFF, the unit
will operate in the selected mode whenever the set-
point is within that range.
START--STOP = The unit will always operate in
Start--Stop whenever the setpoint is between the
minimum & maximum temperatures for that range
(see below).
CONTINUOUS = The unit will always operate in
Continuous Run whenever the setpoint is between
the minimum & maximum temperatures for that
range (see below).