62-110395-9
CONFIGURATION
SELECTIONS DESCRIPTION
RANGE (1--2) MINIMUM TEMP
-- 2 2 °FTO+89.6°F
(--30°Cto+32°C)
in 0.1°For°Cin-
crements
Select the lowest temperature desired for either
Range 1 and/or Range 2.
RANGE (1--2) MAXIMUM TEMP
-- 2 2 °FTO+89.6°F
(--30°Cto+32°C)
in 0.1°For°Cin-
crements
Select the highest temperature desired for either
Range 1 and/or Range 2.
MIN SETPOINT
C2 MIN SETPOINT
C3 MIN SETPOINT
-- 2 2 °F TO +89.6°F
(--30°Cto+30°C)
in 0.1°ForCincre-
ments
Select the lowest temperature that will ever be used
as setpoint. Setpoint can not be set lower than this
value.
MAX SETPOINT
C2 MAX SETPOINT
C3 MAX SETPOINT
-- 2 2 °FTO+89.6°F
(--30°Cto+32°C)
in 0.1°For°Cin-
crements
Select the highest temperature that will ever be
used as setpoint. Setpoint can not be set higher
than this value.
NO POWER
NOT INSTALLED /
INSTALLED &
SHUTDOWN
SWITCH TO EN-
GINE
NOT INSTALLED -- Standby operation is not
installed
INSTALLED & SHUTDOWN -- Standby is installed.
If standby power is lost unit will shut down
SWITCH TO ENGINE -- Standby is installed. If
standby power is lost diesel engine will start.
S/S PARAMETERS
TOGETHER
SEPARATE
TOGETHER = When the Minimum Run Time, Mini-
mum Off Time, Maximum Off Time, and Override
Temperatures are set in the Functional Parameter
List, the same values will be used for both Frozen
and Perishable setpoints.
SEPARATE = When the Minimum Run Time, Mini-
mum Off Time, Maximum Off Time, and Override
Temperatures are set in the Functional Parameter
List, different values may be entered for Perishable
and Frozen setpoints.
REMOTE TEMP SENSOR 1
(Optional)
REMOTE TEMP SENSOR 2
(Optional and Available for 2
Compartment Units Only)
ON / OFF ON=A remote sensor has been added to the unit,
and connected into the wire harness at Remote
Temp Sensor (1--2) plug. This enables Remote
Temp Sensor ( 1--2) to be read through the Data
List.
OFF=There is no Remote Sensor (1--2) in this unit.
DOOR SWITCH:
(Optional)
NOT AVAILABLE FOR 3
COMPARTMENT UNITS
SWITCH NOT
INSTALLED
DOOR OPEN
SWITCH OPEN
DOOR OPEN
SWITCH CLOSED
SWITCH NOT INSTALLED = There is no door
switch in this box.
DOOR OPEN SWITCH OPEN = A Door Switch has
been installed on one of the box doors. The switch
contacts will be OPEN whenever the door is OPEN.
DOOR OPEN SWITCH CLOSED = A Door Switch
has been installed on one of the box doors. The
switch contacts will be CLOSED whenever the door
is OPEN.