EasyManua.ls Logo

Carrier VECTOR 1800 MT - Page 267

Carrier VECTOR 1800 MT
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-1462-11039
8.9.4 Generator Removal
WARNING
Be aware of HIGH VOLTAGE supplied by the
generator as the unit may start
automatically. Before servicing the unit,
make sure the START/RUN--OFF switch is in
the OFF position. Also disconnect the
negative battery cable. NEVER
dis--assemble the generator: HIGH
MAGNETIC FIELD INSIDE! Pacemaker
wearers must stay clear of the unit while
operating as the power generator supplies
HIGH VOLTAGE AND MAGNETIC FIELD.
2.
3.
1. Disconnect the battery.
2. Remove the engine oil fill cap.
3. Remove muffler nuts.
Figure 8 --12 Generator Removal
4.
6.
5.
4. Disconnect ground wire.
5. Disconnect the 2 generator sensors (GENT)
(if existing)
6. Cut the 3 generator cables (near ground
strap)
Figure 8 --13 Generator Removal
7.
8.
8.
9.
7. Loosen the harness plate on the right side (4
bolts)
8. Remove the engine frame bolts (H1, H2, H3,
-- H2 shorter than H3)
9. Place the engine support tool (P/N
SKM 5670)
10. Unscrew the engine frame bolt
Figure 8 --14 Generator Removal

Table of Contents