62-11039 3-14
3.10 MANUAL DEFROST
COOL DEFROST ALARM START-STOP
SETPOINT BOX TEMPERATURE
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT CONTINUOUS
DEFROST CYCLE STARTED
-20
START--STOP/
CONTINUOUS
2
DEFROST LIGHT
1. Press the MANUAL DEFROST key. The DEFROST light will come on
and the MessageCenter will display “DEFROST CYCLE STARTED” for
5 seconds, or flash CANNOT START DEFROST CYCLE” for 5 sec-
onds.
d
F
3.10.1 Manual Defrost
The defrost mode can not be manually initiated if:
“CANNOT START DEFROST CYCLE is displayed
when the manual defrost key is pressed thus indicat-
ing that none of the Defrost Termination Tempera-
ture Sensors (1DTT, 2DTT or 3DTT) is below 40°F
(4°C).
The engine has not run 15 seconds after starting.
The unit is in PC Mode.
The unit is in Pretrip.
There is an active shutdown Alarm.
TIP
The Manual Defrost Key can be used at any
time to start a Defrost Cycle as long as one of
the DTTs is below 40°F(4.4°C).
NOTE
All compartments will go into defrost at the
same time.
NOTE
Refer to Section 4.4.10 for more detailed infor-
mation on Defrost.

Table of Contents