62-11039 3-28
3.18 STOPPING UNIT
WARNING
Always place RS in the OFF position and turn off the high voltage power supply before discon-
necting the high voltage power plug from the unit.
off
STANDBY
ENGINE
1. To stop the unit, place the START/RUN -
OFF switch in the OFF position.
The diesel engine will stop and the microprocessor
controller will turn off. The Microprocessor Main
Display, MessageCenter, and all indicator LEDs will also
turn off.
NOTE
Due to internal processing within the micro-
processor, turning the RS OFF then back to
START/RUN will result ina4to50second
delay between the display going off and com-
ing back on again.
NOTE
The microprocessor will close the Electronic
Expansion Valve (EVXV) and the CSMV be-
fore turning off.
NOTE
If all compartments are off and the RS is still
in the START/RUN position, the unit will stop
but the microprocessor will stay energized.