20
CAL 3-3
Function: Setting Weight
Range of set value: 1 ~ 99,999
KEY DISPLAY DESCRIPTION
LOAD 1
It means the weight setting mode.
(Number = multi calibration number)
W=100.00
100.00 (unit: Kg or Ton)
Key : Value change
Key : Digit change
ZERO Key : Cancel
SET Key : Save and next
menu
W= 0.10
0.10 (unit: Kg or Ton)
Note 1. Set the weight within a range of 10% ~ 100%.
CAL 3-4
Function: Weight Calibration
KEY DISPLAY DESCRIPTION
LoAd
Load the weight set in CAL 3-3 and press the
setup key.
12345
The current weight value is displayed.
Confirm 'Stable' and press the setup key.
ZERO Key : Cancel
SET Key : Save and next
menu
- - -
Span adjustment in progress...
Note 1. CAL 3-3 and CAL 3-4 are repeated as many as STEP is set in CAL 3-1.
At this time, the weight value should be set to a value greater than the previous one.
Note 2. Move to CAL-3 if the span adjustment is over with no error.