EasyManua.ls Logo

CAS PB Series - C4 Setting; C4-1 Setting

CAS PB Series
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Service Manual
PB
Series
REV NO
:
4.1.1. C4 Setting
4.1.1.1. C4-1 Setting
BIT 6~7 Initial Zero range
3
5%
2
10%
1
3%
0
2%
BIT5 Last digit enable
0
Disable
1
Enable
BIT4 Key zero percent
0
±
3% key zero percent
1
±
2% key zero percent
BIT 2~3 Successive tare
3
(+), (-) All Direction successive Tare
2
(+) Direction successive Tare
1
(-) Direction successive Tare
0
One Time tare
BIT0~1 Zero mark type
0 Gross zero indication
1 Net zero indication
2 Both(gross and net) zero indication
4.1.1.2. C4-3 Setting
BIT7 Dot Type
0
"." dot
1
"," comma
BIT6
Use Preset tare
(PB can’t use)
0
Don't use
1
Use
BIT5 Use Back light
0
Don't use
1
Use
BIT4
Use Head message
(PB can’t use)
0
Don't use
1
Use
BIT3 Use gram
0
Don't use
1
Use
BIT2 Use oz
0
Don't use
1
Use
BIT1 Use lb
0
Don't use
1
Use
BIT0 Use Kg
0
Don't use
1
Use

Other manuals for CAS PB Series