EasyManua.ls Logo

Case CX300C - Bringing the machine up to operating temperature

Case CX300C
288 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-OPERATINGINSTRUCTIONS
Bringingthemachineuptooperatingtemperature
NOTICE:Normaloperatingtemperatureofthehydraulicuidisbetween50°C(122.0°F)and80°C(176.0°F),in
themiddleofthetemperatureindicator.
Afterstartingtheengineandbeforeusingthemachine,allowthehydraulicuidtoreachatemperatureof20°C(68.0
°F),asindicatedbytheappearanceofthersttwosegmentsonthehydraulicuidtemperatureindicator.(Referto
page3-18).
Engineautomaticwarm-up
Oncetheenginehasstarted,thewarming-upprocessbeginsautomatically.Atrst,enginespeedisheldatapre-
determined,lowlevel.Asthetemperatureincreases,enginespeedincreasesinproportion.Itispossibletointerrupt
thewarming-upprocessatanytime,simplybymanuallychangingenginespeedorbyoperatingoneofthecontrol
levers.Warming-uptakesapproximately5to10minutes.
Manualenginewarm-up
Withtheenginethrottlebuttonaquarteropen,starttheengineandallowittorunapproximatelyfor5to10minutes.
Whenthecoolanttemperaturereachesthesecondsegment,carryoutthehydraulicuidwarm-upprocedure.
Hydraulicuidwarm-up
1.Turntheenginethrottlebuttontohalf-openposition.Pushthefunctioncancellationleverforward(safetybarin
outwardposition).Operatethebucketcontrolslowlyuntilthebucketiscompletelyclosed.Operatethearmre-
tractingcontrolslowlyuntilthearmiscompletelyretractedandholdthecontrolinthispositionfor30seconds.
Duringthistimethetemperatureofthehydraulicuidwillincrease.
2.After30seconds,extendthearmcompletelyandholdthecontrolinthispositionafurther30seconds.
3.Continuethearmextendingandretractingprocedureuntilthetemperaturerises(rsttwosegmentsofthetem-
peratureindicator).
4.Operatethetravelandattachmentcontrolsthreeorfourtimestocirculatethehydraulicuid.
4-9

Table of Contents

Related product manuals