EasyManua.ls Logo

Case CX300C - Batteries access; Checking the charge state of a maintenance-free battery; Checking the electrolyte level of a maintenance-type battery

Case CX300C
288 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-MAINTENANCE
Batteriesaccess
Toaccessthebatteries,opentheleft-handreardoorthen
removetheskidplate.
MCHP8N-0111
Checkingthechargestateofamaintenance-freebattery
Thechargeindicatoronthebatteryshowsthestateof
chargeofthebattery.
Ifthecolouris:
Green;thechargeiscorrect.
Black;insufcientcharge.Rechargethebatteryuntil
theindicatorturnsgreen.
Transparent(colourless);replacethebatteryassoon
aspossible.
H1COZX-0022
Checkingtheelectrolytelevelofamaintenance-typebattery
Removethecellcapsandcheckthelevelineachbatteries
cell.Thelevelshouldbebetween10mm(0.4in)and
15mm(0.6in)abovetheplates.Adddistilledwaterif
necessary,theninstallthecellcaps.
ATTENTION:Whenaddingdistilledwaterattempera-
turesbelow0°C(32.0°F),thebatteriesmustbecharged
ortheenginerunfortwohoursapproximatelyinorder
toensurethatthedistilledwaterandtheelectrolyteare
properlymixed.
NOTE:Makesurethebatteryterminalsarecleanand
coatedwithgreaseandthatthecablesareproperlytight-
ened.
9K4QUU-001A3
6-77

Table of Contents